SUPPORT LOGIN

Powermetrix - My WordPress Blog

Follow Us on FacebookFollow Us on TwitterFollow Us on LinkedInFollow Us on YouTube
  • Home
  • Applications
    • Meter Site Testing
    • Instrument Transformer Testing
    • Revenue Protection
  • Customers
    • Utility Companies
    • Service Providers
    • Industrial Applications
    • Powermetrix Educational Partnerships
  • Products
    • Electric Meter Training Benches
      • PowerMaster® Self Contained Metering Site Training Bench
      • PowerMaster® Transformer Rated Metering Site Training Bench
      • PowerMaster® Transformer Rated and Self-Contained Metering Site Training Bench
      • PowerMaster® Training Administrator Station
    • PowerMaster® 7 Series
    • PowerMaster® 4 Series
    • PowerMaster® 3 Series
    • Accessories
  • Support
    • Powermetrix Technical Library
    • Product Repair & Service (RMA)
    • Powermetrix Training Center
    • Powermetrix Webinar Series
    • PMX Meter School
    • Frequently Asked Questions
  • About Us
  • News
  • Calendar
  • Contact Us
    • Corporate
    • Contact Sales
    • Contact Support
    • Rep Partners

PowerMaster® 3 Series

Introducing the Revolutionary PowerMaster® 3 Series Hand-held 3-Phase Meter

The PowerMaster® 3 Series is an ultra-compact field instrument with a true 3-phase analyzing reference standard that performs various metering site accuracy tests.

Customer load Meter Testing, CT/PT ratio testing, CT/PT burden measurement, meter register/demand testing, and wiring verification are all easily performed with this extremely portable, hand-held 3-phase power analyzer.

In addition, with the new Model 335, phantom load meter testing and CT burden added testing are available to complete your field-testing needs. With many advanced features, this new pint-sized 3-phase power analyzer is revolutionizing field testing as we know it.

Contact our sales staff today and ask them about:

  • Testing Meters, CTs & PTs
  • Diagnosing Metering Site Errors
  • CATIV 600V Safety Rating
Download Product Brochure

  •  
  •  
Contact Sales
PowerMaster 3 Series

PowerMaster® 3 Series Video Demo

PowerMaster® 3 Series Load Box & Burden Accessory Demo
  • Request a Quote
  • Accessories
  • Applications
  • Features
  • Specifications
    (Check all that apply)
  • This field is for validation purposes and should be left unchanged.

 

  • Model 335 Load Box
  • Magnetic IR Pickup
  • Current Flex Probes
  • High Voltage LiteWire Current Probe
Download Product Brochure

 

  • Site Verification
  • Revenue Protection
  • Customer Load Meter Test
  • Phantom Load Meter Test (with Model 335 accessory)
  • CT Ratio Testing
  • CT Burden Measurement
  • CT Burden Added Testing (with Model 335 accessory)
  • Vector Analysis
  • Harmonic Analysis
  • Waveform

 

  • Customer Load Metering Site Testing
  • Phantom Load Metering Site Testing (with Model 335 accessory)
  • True 3 Phase Reference Standard
  • 0.05% Accuracy Class
  • Vector Diagrams
  • Waveforms
  • Harmonics Analysis to the 50th
  • Customer Load Meter Testing
  • Demand/Register Testing
  • CT and PT Ratio Testing
  • CT Burden Added Testing (with Model 335 accessory)
  • CT and PT Burden Measurement
  • CAT IV 600V Rated
  • Compact Handheld Design – Only 3.5 lbs (1.6 kg) 

Download Product Brochure

 

View Sample CT Test Report

 

View Sample CT Burden Measure Report

 

View Sample Customer Load Meter Test Report

 

Download Product Brochure

ANSI SPECIFICATIONS

*Subject to Change

 

Direct Inputs

AC Current:
3 Inputs, 100mA to 20A RMS
4mm Locking Banana Plugs

AC Voltage:
3 Inputs, 46 to 600V RMS
4mm Banana Plugs

Aux. Power:
1 Input, 120 to 240 VAC

Probe Inputs

Two Sets of Three Inputs (Six inputs total)
Resolution and Range Determined by Probe
All Probes are Calibrated Independently of 3 Series

Measurements

Energy:
Wh, VARh, VAh
+/- 0.05% Accuracy (direct current channels)
+/- 0.10% Accuracy (probe channels)

Power:
Watt, VAR, VA
+/- 0.05% Accuracy (direct current channels)
+/- 0.10% Accuracy (probe channels)

Power Factor: -1.00 to 1.00
Harmonics: Up to 50th harmonic (user selectable)

System Connectivity

Pulse Inputs: 2 (meter pulse input, standard input)
Pulse Outputs: 1 (standard output)
USB to PC Port: 1 (connectivity to PC)
USB Ports: 2 (peripheral devices)
RS232 Port: 1 (legacy devices)

Other

Display Resolution: 640 x 480, full color transmissive VGA, LED backlit
Display Size: 5.7 inches
Operating Temperature: -20°C to 50°C (-4°F to 122°F)
Storage Temperature: -30°C to 60°C (-22°F to 140°F)
Humidity: 0 to 95% non-condensing
Internal Battery: 10.8V Li-Ion Rechargeable, 3.07 AHr
Dimensions:
11.6” x 6.2” x 2.0” (295mm x 157mm x 51mm)
Weight: 3.5 lbs (1.6 kg) Not Including Cables
Warranty: 2 Years

*All information subject to change
*See product manual for detailed specs

 IEC SPECIFICATIONS- *Subject to Change

General

Auxiliary Power Voltage Input: 1 Input, 100 to 240 VAC
Internal Battery: 11.1V Li-Ion Rechargeable, 2600 mAh
Auxiliary Power Frequency: 50-60Hz
Power Consumption: 20W
Dimensions:W 295mm x H 157mm x L 51mm
Weight: 1.6 kg Not Including Cables
Display Resolution: 640 x 480, full color
Display Size: 5.7 inches
Operating Temperature: -20°C to 50°C (-4°F to 122°F)
Storage Temperature: -30°C to 60°C (-22°F to 140°F)
Humidity: 0 to 95% non-condensing

Safety

Safety Certification: IEC 61010-1:2010
Measurement Category: 600V CAT IV
Degree of Protection: IP-40

Voltage and Current Measurements

Inputs Range Accuracy
Voltage 46-600V 0.05%
5-46V 0.3%
20mV-5V 0.5%
Current Direct: 100mA-20A 0.05%
1mA-100mA 0.1%
Probe Channel: 50mV-3.2V 0.1% (+/- Probe Error)

CT Burden
Current Direct Voltage Accuracy
0.1A – 20A 0.1V – 5V 0.05%
0.1A 0.02V – 0.1V 0.5% relative to full scale range
PT Burden:
Voltage Current Accuracy
46V – 600V 0.001A- 0.1A 0.2% of full scale range
Pulse Input/Output
Output: 5V
Output Pulse Length: 300ns active low
Max Output Frequency 1’000’000 imp/s
Input 4V – 12V
Max Input Frequency 2MHz

Power and Energy Measurements

Reactive (Q)

Active (P), Apparent(S)
Direct (A,B,C): 100mA-20A 0.05%
1mA-100mA 0.1% (Relative to full scale range)
Direct (A,B,C): 100mA-20A 0.05%
1mA-100mA 0.1% (relative to full scale range)
Temperature Coefficient: -20 – +50 deg C < 0.005%
Frequency 45-65Hz 0.01Hz
Phase Angle 0.00 – 359.99 deg 0.01 deg
PowerFactor -1.000 to +1.000 0.001

Warranty: 1 Year *All information subject to change
*See product manual for detailed specs

  • TEC Systems Logo
  • ACES Systems Logo
  • Materials Testing Logo
  • TEC Nuclear Logo
  • Follow Us on FacebookFollow Us on TwitterFollow Us on LinkedInFollow Us on YouTube

  • Site Terms & Conditions
  • Privacy Policy
  • Career Opportunities

© 2021 Powermetrix Systems. All Rights Reserved.
Custom Site by VIEO Design

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.OkNo