PowerMaster® 3 Series
The Revolutionary PowerMaster® 3 Series Hand-held 3-Phase Meter Tester
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Powermetrix continues its industry leadership with the introduction of Powermetrix Remote Manager (PRM) for the PowerMaster® 3 Series. Powermetrix Remote Manager enables wireless control of essential and various metering site accuracy tests contained within PowerMaster® 3 Series from any Windows compliant system up to 100 feet in any environment, including high EMF environments! Customer load Meter Testing, CT/PT ratio testing, CT/PT burden measurement, meter register/demand testing, and wiring verification are all easily performed with this extremely portable, hand-held 3-phase power analyzer. In addition, with the new Model 335, phantom load meter testing and CT burden added testing are available to complete your field-testing needs.
With many advanced features, handheld pint-sized 3-phase power analyzer is revolutionizing field testing as we know it.
Contact our sales staff today and ask them about:
- Remote Site Testing
- Testing Meters, CTs, & PTs
- Diagnosing Metering Site Errors
- CATIV 600V Safety Rating
- Model 335 Load Box
- Magnetic IR Pickup
- Current Flex Probes
- High Voltage LiteWire Current Probe
- Customer Load Metering Site Testing
- Phantom Load Metering Site Testing (with Model 335 accessory)
- True 3 Phase Reference Standard
- 0.05% Accuracy Class
- Vector Diagrams
- Waveforms
- Harmonics Analysis to the 50th
- Customer Load Meter Testing
- Demand/Register Testing
- CT and PT Ratio Testing
- CT Burden Added Testing (with Model 335 accessory)
- CT and PT Burden Measurement
- CAT IV 600V Rated
- Compact Handheld Design – Only 3.5 lbs (1.6 kg)
ANSI SPECIFICATIONS
*Subject to Change
Direct Inputs
AC Current:
3 Inputs, 100mA to 20A RMS
4mm Locking Banana Plugs
AC Voltage:
3 Inputs, 46 to 600V RMS
4mm Banana Plugs
Aux. Power:
1 Input, 120 to 240 VAC
Probe Inputs
Two Sets of Three Inputs (Six inputs total)
Resolution and Range Determined by Probe
All Probes are Calibrated Independently of 3 Series
Measurements
Energy:
Wh, VARh, VAh
+/- 0.05% Accuracy (direct current channels)
+/- 0.10% Accuracy (probe channels)
Power:
Watt, VAR, VA
+/- 0.05% Accuracy (direct current channels)
+/- 0.10% Accuracy (probe channels)
Power Factor: -1.00 to 1.00
Harmonics: Up to 50th harmonic (user selectable)
System Connectivity
Pulse Inputs: 2 (meter pulse input, standard input)
Pulse Outputs: 1 (standard output)
USB to PC Port: 1 (connectivity to PC)
USB Ports: 2 (peripheral devices)
RS232 Port: 1 (legacy devices)
Other
Display Resolution: 640 x 480, full color transmissive VGA, LED backlit
Display Size: 5.7 inches
Operating Temperature: -20°C to 50°C (-4°F to 122°F)
Storage Temperature: -30°C to 60°C (-22°F to 140°F)
Humidity: 0 to 95% non-condensing
Internal Battery: 10.8V Li-Ion Rechargeable, 3.07 AHr
Dimensions:
11.6” x 6.2” x 2.0” (295mm x 157mm x 51mm)
Weight: 3.5 lbs (1.6 kg) Not Including Cables
Warranty: 2 Years
*All information subject to change
*See product manual for detailed specs
IEC SPECIFICATIONS- *Subject to Change
General
Auxiliary Power Voltage Input: 1 Input, 100 to 240 VAC
Internal Battery: 11.1V Li-Ion Rechargeable, 2600 mAh
Auxiliary Power Frequency: 50-60Hz
Power Consumption: 20W
Dimensions:W 295mm x H 157mm x L 51mm
Weight: 1.6 kg Not Including Cables
Display Resolution: 640 x 480, full color
Display Size: 5.7 inches
Operating Temperature: -20°C to 50°C (-4°F to 122°F)
Storage Temperature: -30°C to 60°C (-22°F to 140°F)
Humidity: 0 to 95% non-condensing
Safety
Safety Certification: IEC 61010-1:2010
Measurement Category: 600V CAT IV
Degree of Protection: IP-40
Voltage and Current Measurements
Inputs | Range | Accuracy |
Voltage | 46-600V | 0.05% |
5-46V | 0.3% | |
20mV-5V | 0.5% | |
Current Direct: | 100mA-20A | 0.05% |
1mA-100mA | 0.1% | |
Probe Channel: | 50mV-3.2V | 0.1% (+/- Probe Error) |
CT Burden
Current Direct | Voltage | Accuracy |
0.1A – 20A | 0.1V – 5V | 0.05% |
0.1A | 0.02V – 0.1V | 0.5% relative to full scale range |
PT Burden: | ||
Voltage | Current | Accuracy |
46V – 600V | 0.001A- 0.1A | 0.2% of full scale range |
Pulse Input/Output | ||
Output: 5V Output Pulse Length: 300ns active low Max Output Frequency 1’000’000 imp/s Input 4V – 12V Max Input Frequency 2MHz |
Power and Energy Measurements
Reactive (Q)
Active (P), Apparent(S) | ||
Direct (A,B,C): | 100mA-20A | 0.05% |
1mA-100mA | 0.1% (Relative to full scale range) | |
Direct (A,B,C): | 100mA-20A | 0.05% |
1mA-100mA | 0.1% (relative to full scale range) | |
Temperature Coefficient: | -20 – +50 deg C | < 0.005% |
Frequency | 45-65Hz | 0.01Hz |
Phase Angle | 0.00 – 359.99 deg | 0.01 deg |
PowerFactor | -1.000 to +1.000 | 0.001 |
Warranty: 1 Year *All information subject to change
*See product manual for detailed specs